Technical reference

The code is two digits, and they are independent

An IP code has the form IP followed by two digits. The first digit describes protection against solid foreign objects, ending at dust. The second describes protection against water, under one specific test. They are separate tests with separate scales, and a high second digit does not imply a high first one or the reverse. Reading the pair as a single 'ruggedness score' is where most mistakes start.

What an IP code does not cover at all

The code answers two narrow questions under laboratory conditions. Several of the things that actually destroy devices in service are outside it entirely, and no digit implies them.

  • Condensation is not an ingress test. Moisture that forms inside an enclosure as it moves between temperatures is a thermal problem, not a sealing one, and a high second digit says nothing about it.
  • Chemical resistance is not covered. Cleaning agents, disinfectants and food-processing chemicals attack seals and housings in ways water does not, and suitability has to be stated separately.
  • Washdown and high-pressure cleaning are not implied. Temperature, detergent and pressure in a cleaning regime go beyond what any ingress digit describes.
  • Freezer suitability is not covered. A sealed enclosure can still be outside its operating temperature range, and the range is a separate specification.
  • Duration and depth beyond the stated test are not covered. A device tested for a defined immersion is not described as submersible in general use.
  • The code says nothing about what happens after a drop. Sealing is tested on an undamaged enclosure, so a cracked housing or a distorted door invalidates the rating in service even though the specification still reads the same.
Worked examples

Worked examples: what the manufacturer documents state, with every condition kept

Each example resolves to a structured IP fact from a Tier-1 document. Where a device states two codes, both are preserved - selecting the more marketable one would misdescribe the device.

Zebra MC3400

ip rating

States TWO codes, IP65 and IP67, with the battery fitted. Read together they describe a dust-protected enclosure tested both against water jets and for temporary immersion. Quoting only IP67 would drop the jet test; quoting only IP65 would drop the immersion test. Neither code alone describes this device.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra MC3450

ip rating

States the same two codes as the MC3400, with the battery fitted. The two models share one spec sheet and one sealing statement, so sealing does not separate them.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra TC58e

ip rating

States IP68 and IP65 with the battery fitted. The first digit is 6 in both, so the enclosure is described as dust-tight rather than merely dust-protected - a different outcome from the MC3400 series' leading 6 and 6 against its own second digits, and the clearest difference between the two sealing statements.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra TC58e

operating temperature

Operating range -20 C to +50 C. Quoted here because sealing and temperature are separate specifications: the sealing statement does not extend the temperature range, and the temperature range does not qualify the sealing.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

How to decide

Choosing against an actual environment

Describe the environment as a set of events rather than as a word like 'wet' or 'dusty'. Each event maps to a different digit, and some map to no digit at all, which is the useful part of the exercise.

  • Separate the water events. Occasional splashing, a hose-down, a dropped device in a puddle and a wash cycle are four different tests, and only some are described by any IP digit.
  • Decide whether dust must be excluded or merely tolerated. If fine powder in the enclosure is unacceptable rather than inconvenient, the first digit must be 6 and a 5 will not do.
  • Treat temperature transitions as a separate requirement. If devices move between a freezer and a loading bay, the question is condensation and operating range, and no ingress digit answers it.
  • Ask about cleaning chemicals explicitly, by name. Suitability for a specific agent is a separate manufacturer statement, and its absence is not approval.
  • Where two codes are stated, keep both in the comparison. A device with two codes has been tested twice and both results are part of what was bought.
  • Remember the enclosure is tested undamaged. In a deployment with real drops, protection in year two depends on housing and door condition, which is a maintenance policy rather than a specification.
Where our evidence stops

What OMG does not know, and will not infer

  • No IP code here supports calling any device waterproof, fully sealed or safe underwater. Those are plain-language absolutes; the codes describe specific tests, and the validator refuses a claim that makes the substitution.
  • The immersion depth and duration behind each stated code are not in the sourced facts. The codes are recorded as codes, and the underlying test conditions would have to come from the standard or from a manufacturer statement before any depth is quoted.
  • Condensation behaviour, chemical resistance, washdown suitability and freezer suitability are not stated for any product here, and none of them follow from an IP code.
  • Whether the stated codes hold with any particular accessory, door or cover open is not stated. The facts record sealing with the battery fitted and nothing further.
  • The other twelve manufacturers in the OMG partner list have no Tier-1 sealing documentation held by OMG. Their absence from this page means not currently evidenced - not that their products seal less well, and not that they do not offer sealed devices.
Evidence

What this page rests on

4 statements on this page resolve to a committed OMG record, which cites the manufacturer document it came from. The operational guidance around them is OMG's own, and is not presented as a manufacturer statement.

  • IEC 60529, Degrees of protection provided by enclosures (IP Code)
  • Zebra product documentation - MC3400 series
  • Zebra product documentation - TC58e
Keep going

Put it to work

Compare products

Two products side by side on what the manufacturer publishes, with unpublished figures shown as not established.

Compare products about Compare products

Ask OMG

Questions answered from the manufacturer's documents, with the source attached and the gaps stated.

Ask a question about Ask OMG

Build my solution

Answer five questions and see which devices the evidence supports for your operation, and which it rules out.

Build my solution about Build my solution

Lifecycle and replacements

What Zebra has announced for the products you run, and which accessories carry over to the successor.

Check a product about Lifecycle and replacements

Technology refresh programs

Phased replacement of an aging fleet, with the swap done on site.

View refresh programs about Technology refresh programs
Next step

Ask OMG about your own devices