Industry

What this hub is about, and the one distinction it insists on

Cold chain work has two deliverables: goods that stayed within temperature, and evidence that they did. A gap in the second is treated as a failure of the first by auditors, customers and insurers, which is why the device decisions here carry more weight than the environment alone would justify.

Six things that are not the same, kept apart on purpose

Most cold-chain specification mistakes are a conflation of two of these six. They are separated here so a requirement can be written against the right one.

  • FREEZER CONFIGURATION a particular build of a product, ordered as such. It is a fact about a part number, and it belongs to the part number rather than to the family.
  • COLD-STORAGE WORKFLOW what people do in and around chilled and frozen space. It is an operational description and it is true regardless of which device is bought.
  • LOW-TEMPERATURE OPERATION a stated operating range. A manufacturer figure about working temperatures, and nothing more.
  • CONDENSATION what happens when something cold enters warm, moist air. It is rated separately where it is rated at all, and a non-condensing rating is not a statement about condensing conditions.
  • HEATED COMPONENTS a physical feature of some builds, typically a heated screen or scanner window, that exists to address condensation and frost on the surfaces that have to work.
  • BATTERY BEHAVIOUR IN COLD a chemistry and charging subject with its own rules, which is why some builds have their own battery rather than the standard one.
  • Writing a requirement that names which of the six it means is the single cheapest thing a buyer can do here. Most quotes OMG is asked to review conflate the first with the third.

Workflow map: twelve jobs across a temperature boundary

Cold chain work is ordinary warehouse and transport work with a boundary drawn through the middle of it. The map below is organised by where the boundary falls, because that is where the device requirements change.

  • INBOUND RECEIVING AND TEMPERATURE CHECK verifying goods and their temperature at the door, which is a record-creating step before it is a goods-receipt step.
  • QUALITY AND REJECTION DECISIONS deciding what happens to a load that arrived out of range, with the evidence captured at the point of decision rather than reconstructed later.
  • PUT-AWAY INTO CHILLED OR FROZEN SPACE the first crossing, and often the first place a device spends real time in the cold.
  • BLAST FREEZING AND TEMPERING moving stock deliberately between temperatures, where the stock's state changes and the system has to agree about it.
  • FROZEN PICKING picking in the coldest space in the building, with gloves, usually against a time limit set by people rather than by equipment.
  • REPLENISHMENT TO A CHILLED PACKING AREA the zone that is neither ambient nor freezer, and the one most often specified as if it were an office.
  • VALUE-ADD, PACKING AND LABELLING applying labels in a cold, damp area, which is a media and adhesive problem before it is a printer problem.
  • DOCK LOADING AND TRAILER CHECKS the worst place in the building: ambient air, cold goods, open doors, and everything condensing.
  • TRANSPORT AND THE CONTINUOUS RECORD monitoring in transit, where the device in the cab and the recorder in the trailer are different problems.
  • LAST-MILE DELIVERY handover with a temperature record attached, often outdoors, often in the rain, often to someone who wants a signature quickly.
  • RETURNS, RECALLS AND DISPOSAL where the record is read rather than written, and where its gaps become decisions about stock.
  • DEVICE HANDLING ACROSS SHIFTS charging, staging and swapping units that have been in and out of the cold all day. This is a workflow, and it is the one most often left unowned.

Zones, and why a site cannot be specified as one environment

Treating a cold-chain site as one cold place is how the wrong device ends up in two of its zones. Four zones with different requirements usually exist within a hundred metres of each other.

  • AMBIENT OFFICE AND YARD ordinary conditions, where ordinary equipment is appropriate and where cold-rated equipment is simply more expensive.
  • CHILLED SPACE above freezing but near it, damp, with a wet floor. Many general-purpose devices state a lower limit at or just below this zone's temperature, which makes it the zone where specifications are most often wrong by a small margin.
  • FROZEN SPACE well below freezing, dry air inside, frost on every surface that has recently been through a door.
  • THE BOUNDARY ITSELF doors, airlocks, docks and vestibules, where warm moist air meets cold surfaces. Nothing in a specification sheet describes this zone, and it is where equipment fails.
  • A device crosses zones; a fixed installation does not. That is the strongest argument for separating handheld specification from mounted and fixed equipment on a cold-chain site.
  • Specify per zone and record which zone each device population lives in. An estate where nobody can say which devices go into the freezer cannot be refreshed accurately either.

Condensation, which is usually what actually fails

Cold equipment brought into warm, moist air collects water on and inside it. This is the mechanism behind most cold-chain device failures, and it is a separate subject from the operating range in every manufacturer document OMG holds.

  • The direction that causes trouble is cold to warm, not warm to cold. A device carried out of a freezer into a loading bay is the failure case, not the device going in.
  • Screens and scanner windows fog, and a fogged window is a device that cannot scan even though nothing is broken. That is the problem heated components exist to address.
  • Water that condenses inside a device is not something a sealing rating speaks to. Ingress ratings describe water applied from outside under test conditions.
  • A non-condensing humidity rating is a statement about the conditions of a test, not a tolerance for condensing conditions. Where a build is rated for condensing conditions, that is a different and explicitly stated rating.
  • Operational mitigations work and cost nothing: stage devices in a vestibule, keep a device in the cold for a whole task rather than crossing repeatedly, and avoid charging a unit that has just come out of a freezer until it has warmed.
  • Count the crossings per shift before specifying. A device crossing twice a shift and a device crossing thirty times are different requirements with the same temperature range.

Devices: specify by zone and by crossing rate

The useful question is not how cold it gets but where the device lives and how often it moves. Two devices with the same stated range can be wholly different propositions in a freezer.

  • For work inside frozen space, a build intended for it - with the heated surfaces and its own battery - is the only honest answer. Operational care does not substitute for the build.
  • For chilled space, check the lower bound rather than assuming. Many general devices stop at or just above the temperature of a chilled room, which is a specification failure of one or two degrees.
  • For the ambient parts of the site, specify ambient equipment. Buying freezer builds for a whole estate to simplify purchasing is a common and expensive error.
  • Fixed and mounted equipment in the cold is a different project from handhelds: it does not warm up between tasks, and its cabling, power and mounting all sit in the cold permanently.
  • Keypads earn their place in cold work in a way they do not elsewhere, because a gloved hand on a touchscreen is slower and less accurate, and a glove that has to come off is a hand that gets cold.
  • Screen brightness and glare matter at the dock, where the device moves between a dim freezer and daylight within seconds.
  • Accessories must be specified for the zone too. A holster, strap or cradle that is fine in ambient conditions can become stiff, brittle or icy, and an accessory that is unpleasant to use in the cold is one that gets abandoned.

Labels, media and printing in and around the cold

Labels fail in cold chains more often than devices do, and a label that falls off a frozen carton takes the record with it. This is mostly a media decision, which means it is mostly a decision nobody owns.

  • Adhesives are temperature-rated, and the rating that matters is the temperature of the SURFACE at the moment of application, not the temperature of the room.
  • Applying a label to a frosted or wet carton is the common failure. Frost is a release layer, and no adhesive specification survives it.
  • Print where the surface is dry if there is any choice: labelling before chilling, or in a packing area, beats labelling in a freezer.
  • Direct thermal media behaves differently in cold and damp conditions, and a label that smudges or fades takes its barcode with it.
  • Specify the media as deliberately as the printer, including liner, adhesive and face stock, and test with the actual cartons from the actual process.
  • Have a reprint path at the point of use. In a cold chain a missing or unreadable label becomes a quarantined pallet, which costs far more than a printer.
  • Mobile printing in frozen space is possible and is rarely the best answer. Printing at the boundary and carrying the labels in usually wins.

Batteries, power and charging

Cold affects batteries more visibly than it affects anything else on a device, and it affects charging more than it affects running.

  • Capacity available in the cold is lower than the rating. Plan the shift on what the device delivers in the freezer rather than on its stated capacity.
  • Charging a cold battery is the part to be careful about. Charging a unit that has just left a freezer is both a condensation risk and a battery one, so warming before charging belongs in the procedure.
  • Where a build has a battery of its own for cold work, treat the battery as part of that build. A standard spare put into a cold-build device defeats the reason it was bought.
  • Hot-swap capability is worth more here than elsewhere, because it keeps a device out of the warm room between tasks.
  • Keep charging and staging on the warm side of the boundary, in a defined place, with enough positions for every device that crosses.
  • Battery health degrades faster in cold-chain duty. Monitor it, and plan replacement by measurement rather than by age.

Connectivity, monitoring and the transport leg

Freezers are hostile to radio and to infrastructure, and the transport leg adds a second, separate monitoring problem that is often confused with the device one.

  • Frozen space is metal racking, dense product and often ice. Coverage inside a freezer must be surveyed inside the freezer, full, with the doors shut.
  • Access points and cabling inside the cold are an installation problem of their own, and specifying them as if they were in a dry warehouse is the usual source of a second project.
  • Design the picking workflow to tolerate a coverage gap. A pick that cannot complete without a round trip to the door produces either lost records or a propped-open freezer door.
  • In-transit temperature monitoring is a separate system from the driver's device, with its own record. Do not let a specification quietly assume the handheld is doing it.
  • Decide where the authoritative temperature record lives, and make sure what the driver sees and what the auditor reads come from the same place.
  • At handover, the record and the signature are one transaction operationally and two systems technically. That join is worth testing before go-live.

People, deployment and lifecycle

Cold-chain operations are limited by people before equipment, and a device that ignores that gets worked around.

  • Gloves are not optional, so every interaction has to work gloved, including scanning triggers, keypads, screens and anything requiring a precise tap.
  • Shift time in frozen space is limited by welfare rules and by human tolerance. A workflow that adds a minute per pick is removing picking time from a bounded shift.
  • Devices get dropped more in the cold, because gloves reduce grip and because surfaces are slippery. Specify for drops onto hard, cold floors.
  • Stage and configure devices before they reach a cold site, and give the site one defined place where devices live, charge and warm up.
  • Label the device population by zone, physically, so a freezer build does not drift into an ambient role or the reverse.
  • Track announced end-of-sale and end-of-service per model. OMG keeps lifecycle and replacement records per family at /pages/resources-lifecycle and document references at /pages/resources-documentation; this hub cites those rather than restating them.
  • Replace on measured condition in this industry rather than on age alone. Cold-chain duty is harder on batteries and on seals than any other environment OMG builds for.
Worked examples

Worked examples: what the manufacturer documents state, per configuration

Workflow guidance above is OMG expertise. Each statement below resolves to a fact in a committed record and declares the configuration it relies on. A freezer figure and a standard figure are different facts about different builds, so no claim here carries one under the other's name.

Zebra MC9400 / MC9450, Standard configuration

Stated for the Standard configuration · operating temperature

The Standard configuration is stated from -20 C to +50 C. That covers a chilled room and a dock comfortably, and it is the figure most quotes are actually built on - which is why a requirement for frozen space has to say so explicitly rather than relying on the family name.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra MC9400 / MC9450, Freezer configuration

Stated for the Freezer configuration · operating temperature

The Freezer configuration is stated from -30 C to +50 C: ten degrees lower at the bottom, same at the top. The ten degrees are the reason the build exists, and they are a property of that build - which is why OMG will not describe a device as freezer-capable on the strength of the family being available in a freezer configuration.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra MC9400 / MC9450, Freezer configuration

Stated for the Freezer configuration · humidity

5% to 95% CONDENSING, stated as a condensation-resistant model with heaters for the scanner exit window and the touch panel glass. The condition travels with the figure: the condensing rating and the heated surfaces are one statement, so a device without those surfaces is not covered by it even if its temperature range looks similar.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra MC9400 / MC9450, Standard configuration

Stated for the Standard configuration · humidity

5% to 95% NON-condensing, for the Standard configuration of the same family. One word apart from the figure above, and it is the word that decides whether a device belongs on the cold side of a boundary - which is the clearest demonstration on this site of why OMG records humidity per configuration rather than per model.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra MC9400 / MC9450, Freezer configuration

Stated for the Freezer configuration · environment configuration

Zebra states that the freezer model includes a heated touch panel and scanner exit window, plus a freezer-rated battery. Three distinct things, one of which is a battery - so the cold build is not only a tolerance claim, and a standard spare battery dropped into it removes part of what was bought.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra MC9400 / MC9450

storage temperature

Storage is stated from -40 C to +70 C, and Zebra states it without distinguishing the configurations. Storage is not operation: this is the figure for a device switched off in a trailer or a yard overnight, and it is not permission to work at those temperatures.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra TC58e touch computer

operating temperature

Stated from -20 C to +50 C for a general-purpose touch computer. On paper that reaches into frozen space; in practice this device is specified without heated surfaces and with a non-condensing humidity rating, so the range alone is the wrong basis for putting it in a freezer. Range and condensation are separate questions and this is the device that shows why.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra TC58e touch computer

humidity

5% to 95% non-condensing. For a device crossing a cold-chain boundary several times a shift this is the figure to read first, because non-condensing describes the test conditions and the boundary is exactly where conditions stop being non-condensing.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

Zebra CR2278 Presentation Cradle, operating temperature

operating temperature

A counter scanning cradle is stated from 0 C to +40 C. A chilled packing area can sit below the bottom of that range, so a scanning station that works in a warm despatch office is not automatically a scanning station for a chilled one - and because this is the accessory's own rating, the scanner it serves does not settle the question.

Resolves to a committed OMG record, which cites the manufacturer document it came from.

How to decide

Patterns that tend to hold in cold chain

OMG recommendations rather than manufacturer statements, offered so they can be argued with against a specific site.

  • Write the requirement per zone, and say which of the six subjects each line is about. Most disputed quotes in this industry are a conflation of configuration with operating range.
  • Count crossings per shift and treat that as a first-class requirement alongside temperature.
  • Buy the cold build for cold work rather than managing the gap operationally, and buy ambient equipment for ambient work rather than standardising upward.
  • Check the lower bound for chilled areas specifically. The failures there are small margins, and they are the ones nobody checks because the room is not cold enough to worry about.
  • Put the charging and staging position on the warm side, in one defined place, sized for every device that crosses.
  • Decide labelling position by surface condition, not by process convenience, and test with real cartons straight out of the real process.
  • Survey radio coverage inside the freezer, full, with the doors closed, and design picking to tolerate a gap.
  • Separate the in-transit temperature record from the handheld workflow explicitly, and test the join at handover.
  • Make the device population visibly zoned, so a cold build cannot drift into an ambient role unnoticed.
  • Ask what the operation currently does when a label is unreadable or a record is missing. The answer describes the real cost of getting this wrong better than any specification does.
How to decide

Next steps

Three entry points, depending on whether the question is specification, operation or evidence.

  • Read the cold storage and freezer device selection guide first if the question is which rating means what. It is the specification companion to this page and it keeps the terms apart in the same way.
  • Use the guided solution builder when the zones and workflows are known, so the cold builds, batteries and accessories are specified per zone rather than per site.
  • Ask for a workflow assessment when the operation is losing records, labels or picking time rather than devices - and bring the crossing count, the chilled-area temperature and one real carton. Those three facts settle more arguments than a specification sheet.
Where our evidence stops

What this hub does not claim

  • No OMG part number is identified as the Freezer configuration of any product. The MC9400 and MC9450 facts above are Zebra's per-configuration statements; which configuration a given OMG SKU is remains unresolved, and this hub will not close that gap by inference from a SKU suffix or a product title.
  • Cold storage is not used anywhere here as a product configuration label. It names a workflow and a place, because no source OMG holds uses it as a configuration name.
  • No runtime, capacity retention or charge-time figure in the cold is claimed for any device or battery. The hub states that cold reduces available capacity as general engineering; no manufacturer figure OMG holds quantifies it for a specific product.
  • No claim is made that any device, build or heated component prevents condensation. The sourced statement is that a particular configuration is rated for condensing conditions and includes heated surfaces, which is what Zebra states and not a promise about outcomes.
  • No adhesive, media or label durability claim is sourced here. The media guidance is OMG experience, and the ratings that would support it are the media manufacturers', which OMG does not hold as Tier-1 documents.
  • No claim is made that any device or configuration satisfies a food-safety, pharmaceutical or temperature-monitoring regulation, in any jurisdiction. Those are compliance questions about a whole process, and OMG holds no compliance evidence for any product.
  • No in-transit temperature recorder is specified or compared here. It is named as a separate system because it is one, not because OMG holds evidence about particular recorders.
  • Storage temperature is cited as storage. It is not offered as an operating range at those temperatures, and Zebra states it without distinguishing the configurations, so no configuration-specific storage figure is claimed.
  • Devices from the other manufacturers in the OMG partner list are not compared here, because OMG holds no Tier-1 documentation for them. Not currently evidenced is not a judgement about their products.
Evidence

What this page rests on

9 statements on this page resolve to a committed OMG record, which cites the manufacturer document it came from. The operational guidance around them is OMG's own, and is not presented as a manufacturer statement.

  • Zebra product documentation - MC9400 series
  • Zebra product documentation - DS2200 series
  • Zebra product documentation - TC58e
  • Zebra support documentation (product lifecycle and replacement notices)
  • /pages/resources-cold-storage-selection for the specification guide this hub does not restate
Keep going

Take it from here

Build my solution

Answer five questions and see which devices the evidence supports for your operation, and which it rules out.

Build my solution about Build my solution

Compare products

Two products side by side on what the manufacturer publishes, with unpublished figures shown as not established.

Compare products about Compare products

Plan a project or rollout

More than one product: sites, phases, configuration and a go-live date, handled as one project.

Plan a project about Plan a project or rollout

Zebra at OMG

The deepest manufacturer center: what the documentation establishes, and where it stops.

View the Zebra center about Zebra at OMG

Nationwide deployment

Onsite installation nationwide for the systems OMG sells, from one site to many.

View nationwide deployment about Nationwide deployment
Next step

Tell us which part of this operation is failing