Zebra TC58e mobile computer
ip rating
Sealing is stated as IP68 and IP65 with the battery fitted, per the applicable IEC sealing specifications. That covers rain and hose-down cleaning on the manufacturer's terms; it is a sealing rating, not a statement about any cleaning agent.
Resolves to a committed OMG record, which cites the manufacturer document it came from.
Zebra TC58e mobile computer
operating temperature
The operating range is stated from -20 C to +50 C (-4 F to +122 F). A closed vehicle in summer can exceed the top of that range, which is why where the device is stored between shifts is a specification question.
Resolves to a committed OMG record, which cites the manufacturer document it came from.
Zebra ZQ320 Plus mobile printer
operating temperature
The three-inch mobile printer OMG features is stated to operate from -15 C to +50 C (5 F to +122 F). OMG's current record of this printer is the indoor configuration, so its suitability for a particular vehicle installation is confirmed per project rather than assumed.
Resolves to a committed OMG record, which cites the manufacturer document it came from.
Zebra ZQ320 Plus mobile printer
ip rating
Sealing is stated as IP54: protection against dust and splashing water, which is the right expectation for a printer in a console or on a belt, and a lower rating than the handheld it pairs with.
Resolves to a committed OMG record, which cites the manufacturer document it came from.
Zebra ZQ310 Plus mobile printer
operating temperature
The two-inch mobile printer is stated to the same -15 C to +50 C range as its three-inch sibling, so the choice between them is print width and media, not environment.
Resolves to a committed OMG record, which cites the manufacturer document it came from.
Zebra DS3608-HD ultra-rugged scanner, corded
ip rating
The high-density scanner OMG recommends for property-room intake is stated as IP65 and IP68 sealed per the applicable IEC specifications - a scanner that can be wiped down at an intake counter without concern.
Resolves to a committed OMG record, which cites the manufacturer document it came from.
Zebra DS3608-HD ultra-rugged scanner, corded
operating temperature
Its operating range is stated from -30 C to +50 C (-22 F to +122 F), which covers an unheated evidence garage or a cold-storage property room on the manufacturer's terms.